KIA RIO

Since 2000 of release

Repair and car operation



Kia Rio
+ 1.1. Short acquaintance to the car
+ 2. Engines A3E, А5D
+ 3. Greasing system
+ 4. Cooling system
+ 5. Fuel system
+ 6. Ignition system
+ 7. Coupling
+ 8. A transmission
+ 9. Axes and power shafts
+ 10. A suspension bracket
+ 11. Wheels and tyres
+ 12. A steering
+ 13. Brake system
+ 14. A body
- 15. Air central air
   15.1. Specifications
   15.2. A contour of a central air of air
   15.3. Remarks at replacement of elements of a central air of air
   15.4. Connection of elements of a central air of air
   15.5. Safety measures
   15.6. Check of operational characteristics
   15.7. Diagnostics a central air of air with use of manometres
   15.8. Check of a backlash of coupling of the compressor of the conditioner
   15.9. Check of coupling of the compressor of the conditioner
   15.10. Oil for greasing of the compressor of the conditioner
   15.11. Check of level and доливка oils in the conditioner compressor
   15.12. The air filter of the evaporator
   15.13. The gauge of double pressure
   15.14. The conditioner compressor
   15.15. Condenser check
   15.16. Check of the fan of the condenser
   15.17. Check of the receiver \of a dryer
   15.18. Check of the thermostatic gauge (термистора)
   15.19. Check of the engine of the fan
   15.20. Check of the block of resistors of the engine of the fan
   15.21. The switch of giving of air in car salon
   15.22. The control panel air central air
+ 16. The electric equipment


Витамины orthomol Ортомол.




15.1. Specifications
THE GENERAL DATA

The conditioner

Element
The specification
The compressor Type
10PA 15C
Type of oil and volume, sm3
ND–OIL8, 120
Belt of a drive of the compressor of the conditioner Type
4PK
Diameter of a pulley, mm
125

The gauge of double pressure S/W

High pressure, psi (kg/sm2)
45528 (32,00,2)
Low pressure, psi (kg/sm2)
282,8 (2,00,2)
Coolant Type
R134a
Weight, г
65025

The fan and the evaporator

Element
The specification
The fan Rotation direction
Clockwise
Quantity of steps
1–4
Switching of steps
Resistors
The evaporator Type
DRAWN CUP
Inclusion / conditioner deenergizing
OFF:1,00,3C
ON: 2,00,5C
The maximum capacity of cooling, kcal/ch
410010 %
Heater The maximum capacity of heating, kcal/ch
390010 %