KIA RIO

Since 2000 of release

Repair and car operation



Kia Rio
+ 1.1. Short acquaintance to the car
+ 2. Engines A3E, А5D
+ 3. Greasing system
+ 4. Cooling system
- 5. Fuel system
   5.1. Specifications
   5.2. Elements of fuel system
   5.3. A corner of an advancing of ignition
   5.4. Frequency of rotation of idling
   5.5. The gauge of a measuring instrument of the expense of air
   5.6. The detonation gauge
   5.7. The gauge of position throttle заслонки
   5.8. Check of the main relay
   5.9. Check of the relay of the fuel pump
   5.10. Check of pressure of forward and back warmed gauges of oxygen
   5.11. Check of forward and back warmed gauges of oxygen
   5.12. Pressure removal in fuel system
   5.13. Топливопроводы
   5.14. Activization of fuel system
   5.15. Check of residual pressure in fuel system
   5.16. Check of fuel pipelines
   5.17. Check of fuel atomizers
   5.18. Quick-detachable connections
   5.19. The fuel pump
   5.20. A fuel tank
   5.21. Check of system of ventilation картера (PCV)
   5.22. Check of system of catching of steams of fuel
   5.23. Check of the valve of system of catching of steams of fuel
   5.24. Check of the valve of closing of the canister
+ 6. Ignition system
+ 7. Coupling
+ 8. A transmission
+ 9. Axes and power shafts
+ 10. A suspension bracket
+ 11. Wheels and tyres
+ 12. A steering
+ 13. Brake system
+ 14. A body
+ 15. Air central air
+ 16. The electric equipment







5.11. Check of forward and back warmed gauges of oxygen
PERFORMANCE ORDER
1. Switch off ignition.
2. Disconnect a socket of the gauge of oxygen.
3. Connect an ohmmeter between contacts 1 and 3 and measure resistance.

Resistance: 3–7 Ohm at 20С

4. Otherwise, replace the oxygen gauge.

The inhaling moment: 30–49 Nm

5. Connect a socket to the oxygen gauge.

Removal

PERFORMANCE ORDER
1. Disconnect a socket from the warmed gauge of oxygen.
2. A special key turn out the gauge and remove it and a washer.

Installation

PERFORMANCE ORDER
1. Screw the gauge of oxygen with a washer.

The inhaling moment: 30–49 Nm

2. Connect a socket to the oxygen gauge.